Our Highest Performing Double-Glazed Unit to date.

Some seek nothing but the finest. So, when it comes to renovating your home or undertaking a new architectural endeavor why settle for anything but the best? If compromise isn’t quiet your thing, our DGU Max range should be your first and only choice when selecting which double glazing will give you the highest standards of comfort, efficiency and natural light.

Through harnessing the power of LightTech LI Max, DGU Max is our highest performing double glazed unit to date.

Insulation Improvement

%

A warmer space in winter.

As temperatures drop outside, the DGU Max range offers unparalleled insulation properties that keep your home comfortable and energy efficient, even in the coldest months.

With insulation capabilities 77% more effective than standard single glazing, DGU Max ensures that precious warmth remains trapped indoors where it belongs. This also means for lower heating costs over those colder months, making your home more energy efficient.

Solar Control Improvement

A cooler space in summer.

The state of Victoria experiences warm summers, meaning keeping your home cool whilst outdoor temperatures rise is essential.

DGU Max transforms your space allowing for an abundance of natural light whilst keeping cooling costs down and indoor comfort high.

Offering an exceptional 62% increase in solar control, DGU Max not only meets but exceeds the demands of 7-star modern design.

%

Our Highest Performing Double-Glazed Unit to date.

Some seek nothing but the finest. So, when it comes to renovating your home or undertaking a new architectural endeavor why settle for anything but the best? If compromise isn’t quiet your thing, our DGU Max range should be your first and only choice when selecting which double glazing will give you the highest standards of comfort, efficiency and natural light.

Through harnessing the power of LightTech LI Max, DGU Max is our highest performing double glazed unit to date.

%

Insulation Improvement

With insulation capabilities 77% more effective than standard single glazing, DGU Max ensures that precious warmth remains trapped indoors where it belongs. This also means for lower heating costs over those colder months, making your home more energy efficient.

%

Solar Control Improvement

Offering an exceptional 62% increase in solar control, DGU Max not only meets but exceeds the demands of 7-star modern design.

Exploring The Benefits

Year-Round Comfort

The perfect balance of insulation and solar control, experience optimal indoor comfort, year-round.

Superior Solar Control

Reduces heat gain and glare, enhancing comfort while maintaining natural light and reducing cooling costs.

Energy Efficiency

Minimises heat loss and gain, reducing energy consumption and lowering heating and cooling expenses.

Leading Technology

Using the triple silver softcoat technology of LightTech LI Max as standard. Max units offer optimal performance.

UV Protection

Blocks harmful UV rays, protecting interiors from fading and damage while maintaining natural light.

Illuminate Your Space

Maximise natural light, creating brighter interiors while reducing artificial lighting needs.

Enhanced Security

When paired with specific glass types, helps in deterring intruders and providing peace of mind.

Audio Control

Provides superior sound insulation when combined with specific glass types, reducing external noise.

Total Transparency

Ensures crystal clear views with high transparency, offering unobstructed visibility and visual appeal.

See the Difference

Traditionally, achieving a Solar Heat Gain Coefficient (SHGC) rating similiar to that of DGU Max required using Super Grey glass, which only permits 9% visible light, drastically reducing natural light and impairing views. With DGU Max, you enjoy a remarkable 70% visible light transition, ensuring your spaces are filled with natural light while maintaining energy efficiency.

Slide the view to compare the difference and see how DGU Max enhances your views, providing crystal-clear visibility and superior comfort.

70% VLT
9% VLT

Performance Data

All DGU Max units feature LightTech LI Max as the primary pane. This triple silver low iron glass provides superior energy efficiency and clarity. Designed to maximise insulation and light transmission, it’s ideal for homes focused on optimising thermal comfort and reducing energy consumption. Below is the detailed performance data for comparison.

  • Calculation method: LBNL WINDOW Calc Engine v2.4.0, Optics 6.0
  • Environmental Condition: NFRC 100-2000
  • Results are for center-of-glass; does not include effect of frames
  • Location of LowE coating is indicated with surface number
    • #1 indicates exterior surface, #4 indicates the interior surface in a typical double-glazed unit
key2
Tilt

Tilt-angle (°)

Angle of the glass relative to the horizon

  • Typical skylights with a slight pitch: 3-5°
  • Typical windows in vertical walls: 90°
Ug.w

Ug (W/m².K)

Heat-transfer coefficient (center-of-glass)

  • Heat transfer (W) per square meter (m²) of glass for each degree (C) of temperature difference
  • Lower implies better insulation

.w

NFRC 100-2010 Winter Condition

  • The standard environmental condition for Ug quoted in the Window industry
  • Useful as a reference for performance comparison between different glazing systems but can lead to inaccuracies if used to estimate energy consumption
  • Inside Condition:
    • Air and effective room temperature: 21 deg C
    • Room emissivity: 1
  • Outside Condition:
    • Air and effective sky temperature: -18 deg C
    • Effective sky emissivity: 1
    • Convection coefficient: 26 W/m².K
    • Wind speed: 5.5m/s windward
Ug.s

Ug (W/m².K)

Heat-transfer coefficient (center-of-glass)

  • Heat transfer (W) per square meter (m²) of glass for each degree (C) of temperature difference
  • Lower implies better insulation

.s

NFRC 100-2010 Summer Condition

  • The condition used to calculate SHGC
  • Ug.s better represents performance in warm environmental conditions
  • Inside Condition:
    • Air and effective room temperature: 24 deg C
    • Room emissivity: 1
  • Outside Condition:
    • Air and effective sky temperature: 32 deg C
    • Effective sky emissivity: 1
    • Convection coefficient: 15 W/m².K
    • Wind speed: 2.75m/s windward
    • Direct solar radiation: 783W/m²
SHGC

SHGC (Range: 0 – 1)

Solar heat gain coefficient

  • Proportion of solar heat radiation transmitted
  • Generally lower SHGC is desirable for north and west facing windows for reducing air-conditioning cost in summer
  • However, higher SHGC for north and west facing windows would help reduce heating cost in winter
VLT

VLT (Range: 0 – 1)

Visible light transmittance

  • Proportion of visible light (380 - 720nm) transmitted
  • Generally higher VLT is more desirable
VLRf

VLRf (Range: 0 – 1)

Front Visible light reflectance

  • Proportion of visible light reflected on the external side of the IGU
VLRb

VLRb (Range: 0 – 1)

Back Visible light reflectance

  • Proportion of visible light reflected on the room side of the IGU
Tdw

Tdw-ISO (Range: 0 – 1)

Damage weighted transmittance

  • Proportion of colour fading radiation transmitted
  • Lower Tdw-ISO means lower risk of colour fading
  • Accounts for the colour fading potential of both UV and visible spectrum
Tuv

Tuv (Range: 0 – 1)

UV transmittance

  • Proportion of UV radiation (280 - 380nm) transmitted (Range: 0 – 1)
  • Not recommended as a metric for assessing colour fading potential
  • Visible spectrum could account for as much as 40% of the fading from solar radiation
Sel.

Selectivity (VLT/SHGC)

Ratio of visible light transmittance over solar heat gain coefficient

  • Useful for comparing spectral selectiveness of the low-E coating
  • Higher selectivity means less visible light is sacrificed to lower solar heat gain

Example:

  • Sel. in the 0.5 - 0.8 range results from the use of Grey glass; less visible light is transmitted vs infrared radiation
  • Sel. in the 1.9 - 2.2 range results from the use of LightTech LI Max; less infrared radiation is transmitted vs visible light
rgbhex
Nom.

Nominal thicknesses (mm)

List of nominal thicknesses of the IGU components separated by the '+' symbol

Example:

17.52:

  • 17.52mm single-pane laminated glass

6+12+6:

  • DGU made up of:
    • 6mm glass
    • 12mm spacer
    • 6mm glass
Total.

Total thickness (mm)

Total thickness of the glazing system; sum of component thicknesses

Visual fontcolour