SolTech™
SolTech™ Low-E glass products are designed to enhance your home’s energy efficiency, offering superior thermal insulation with options for varying levels of solar control. Engineered specifically for Australian climate regions, SolTech™ helps you meet energy requirements while maintaining low visible light reflection for clear, unobstructed views.
When used in a double glazed unit, SolTech™ offers improved performance, providing better insulation and energy efficiency.
SolTech™ is a registered trademark of Oceania Glass.
Exploring The Benefits
Energy Efficiency
Keep the temperature of your room controlled, lowering your energy consumption and reducing the need for additional heating and cooling.
Low E Coating
Climate
DGU Application
Range of Tones
Colour options are available within the SolTech™ range.
Easy Processing
Performance Data
key2 | Tilt Tilt-angle (°) Angle of the glass relative to the horizon
|
Ug.w Ug (W/m².K) Heat-transfer coefficient (center-of-glass)
.w NFRC 100-2010 Winter Condition
|
Ug.s Ug (W/m².K) Heat-transfer coefficient (center-of-glass)
.s NFRC 100-2010 Summer Condition
|
SHGC SHGC (Range: 0 – 1) Solar heat gain coefficient
|
VLT VLT (Range: 0 – 1) Visible light transmittance
|
VLRf VLRf (Range: 0 – 1) Front Visible light reflectance
|
VLRb VLRb (Range: 0 – 1) Back Visible light reflectance
|
Tdw Tdw-ISO (Range: 0 – 1) Damage weighted transmittance
|
Tuv Tuv (Range: 0 – 1) UV transmittance
|
Sel. Selectivity (VLT/SHGC) Ratio of visible light transmittance over solar heat gain coefficient
Example:
|
rgbhex | Nom. Nominal thicknesses (mm) List of nominal thicknesses of the IGU components separated by the '+' symbol Example: 17.52:
6+12+6:
|
Total. Total thickness (mm) Total thickness of the glazing system; sum of component thicknesses
|
Visual | fontcolour | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Loading ITables v2.1.4 from the internet...
(need help?) |
Applications
External
- Doors
- Windows
- Shop Front
- Roof Glazing
- Frameless Glazing
*Application information attained from Oceania Glass
Specifications
How to Specify
- Available colours and thicknesses:
Neutral
3, 4, 6 & 10mm
Grey
6mm
Select from: Annealed, Heat Strengthened, Toughened or Toughened Heat Soaked* If unsure, select in compliance with AS1288–2021 or manufacturers recommendation. *The glass shall comply with the following performance criteria:
U value
Solar Heat Gain Coefficient (SHGC)
Visible Light Transmission %
Glass Only Values
Total window
Annealed
Annealed glass is glass produced without internal stresses imparted by heat treatment, i.e., rapid cooling, or by toughening or heat strengthening. Annealed glass is not a Grade A safety glass.Toughened
Glass converted to a safety glass by subjection to a process of pre-stressing so that, if fractured, the entire piece disintegrates into small, harmless particles. Toughened glass is a Grade A Safety GlassHeat Soaking
Heat soak testing is a destructive test, which reduces the likelihood of spontaneous breakage by converting impurities such as nickel sulphide inclusions. Heat soaking is required in some but not all applications. If unsure, select in compliance with AS1288-2021 or manufacturers recommendation.Heat Strengthening
All glass which requires extra strength and thermal resistance will be heat strengthened. Heat strengthening increases the strength of annealed glass; however, it is not a substitute for toughened glass. In the event of fracturing heat strengthened glass will crack and tends to remain in glazed position.Toned Glass
Toned glass absorbs a proportion of solar radiation and may require a thermal assessment depending on application.All glass is to be selected and installed in accordance but not exclusively with the following Australian and/or New Zealand Standards
AS 1288 Glass in Buildings Selection and Installation
AS 1170 Minimum Wind Loads on Structures
AS/NZ 2208 Safety Glazing Materials in Buildings
AS/NZ 4666 Insulating Glass Units
AS/NZ 4667 Quality Requirements for cut-to-size and Processed Glass*Specification information attained from Oceania Glass
Considerations
Things to Consider
Application
SolTech when single glazed, must be single glazed with the exposed coating to the inside of the building (surface #2). When incorporated into DGUs solar control glass products are recommended to be glazed with coatings to surface #2.
Glass Processing
Does not require edge deletion for use in insulated glass units.
Thermal Stress and Fracture Risk
Recommend for thermal stress fracture risk assesment.
Large Projects
FGS Glass recommends that for large glazing facades (particularly curtain wall) the customer should highlight this in writing to enable consideration of colour management of supplied product.